Home

Juniper show hardware status

  • Juniper show hardware status. 1X45-D10 and later. Flags Fields. While you are in operation mode “>”, you can use show commands directly. On the local PE, the LDP VPLS connection should be brought down if all CE interfaces go down on the remote PE. This behavior is observed with built-in cards and PIMs (some examples listed below): 1-Port small form-factor pluggable (SFP) Mini-PIM - SRX-MP-1SFP. Required Privilege Level. Node (device) in the chassis cluster ( node0 or node1 ). Jul 11, 2008 · The Script use the Command "show ethernet-switching interfaces", who doesnt exists on the EX4300. The solution below provides information for checking current status, evaluating what is generating the alarm, understanding the alarm, and determining the appropriate action required. Slot number. In Junos OS release 11. Table 1 describes the chassis status LEDs on an EX4650 switch, their colors and states, and the status they indicate. Juniper Networks Hardware Compatibility Tool helps you find the transceivers, line cards, and interface modules that are supported on Juniper Networks products. 1 - Log in to ask questions, share your expertise, or stay connected to content you value. To display PIC hardware information, including the media type description, use the show chassis hardware command. AC Power Supply for a QFX5100 Device | 54. 2. Check if the interface is administratively disabled by executing the show command on the interface. tar. This command is supported on mic and cmic driver code from Junos OS 15. Empty —No FPC is present. On qfx5100-48s switch LED status and Chassis hardware status absent after upgrade JunOS starting from version 19. 2, you can view degraded fabric alarms on a routing matrix based on TX Matrix Plus router with 3D SIBs. iii. Dec 17, 2014 · rj@MHN00525CN01> show chassis pic fpc-slot 0 pic-slot 0 FPC slot 0, PIC slot 0 information: Type 32x 1G/10G SFP/SFP+ Builtin State Online Uptime 56 days, 6 hours, 5 minutes, 6 seconds PIC port information: Fiber Xcvr vendor Wave- Xcvr Port Cable type type Xcvr vendor part number length Firmware 0 10GBASE LR SM FINISAR CORP. QFX5100 System Overview. Sep 30, 2009 · Run the following command on either node to verify that the Chassis Cluster is enabled: show chassis cluster status. Feb 13, 2020 · Solution. Nov 18, 2011 · Last Updated2022-06-09. Information about the backplane, Routing Engine, Power Entry Modules (PEMs), and fan trays. If multiple pseudowires have been configured, the IP address will also show the PW-specific vpls-id-list, for example, 203. In this article, you will find the steps to troubleshoot this problem when it occurs. Jan 16, 2008 · Table 1: show interfaces ge- Output Fields. Starting with Junos OS Release 13. Note: For Junos OS Evolved, only the QFX5200 supports this command. The comment text can be any length, but each comment line must begin with a #. Symptoms. State. x releases, the output of chassis cluster information was bundled together in one big output, which included the status of the LED as well. Juniper ScreenOS CLI Commands (SSG/NetScreen) [Old Device] NetApp clusterd DATA ONTAP CLI Commands (cDOT) NetApp Data ONTAP 7-Mode CLI Commands [Old Device] note. MX240 router—Replace slot with a value from 0 through 2. Specifies the TPM ownership. Junos VLAN Configuration Examples. Status of the fan tray. Reported health value collected by the health monitor. Indicates activity on the hard disk drive. Otherwise, replace fpc-slot with a value from 0 through 31. For example, with version 18. Display the status of the physical interface cards (PICs) of each Flexible PIC Concentrator (FPC) assigned to the guest network function (GNF). show chassis fpc show chassis hardware show chassis fpc pic-status Slot 0 Online EX4600-40F PIC 0 The front panel of an EX3400 switch consists of the following components: RJ-45 ports: Depending on the switch model, 24 or 48 RJ-45 ports (labeled 0 through 23 or 0 through 47) that support 10/100/1000BASE-T Gigabit Ethernet connectors. QFX5100 Device Hardware Overview. For example, the following commands have the same result: user@host> show chassis fpc detail 1 lcc 1 user@host> show chassis fpc detail 9. 4. More detailed information and alarm history can be obtained by querying the hardware which is hosting the optic, basically FPC for MX304. MX80 router—Replace fpc-slot with the value 1. Yellow—Switch is booting. Table 1 lists the output fields for the show chassis cluster status command. Aug 22, 2020 · This is similar to LD. As we already know, the “show” works from the operational mode. 1-Port Gigabit Ethernet small form-factor For example, the following commands have the same result: user@host> show chassis environment fpc 1 lcc 1 user@host> show chassis environment fpc 9. The following are the basic steps required for configuring a Chassis Cluster on SRX240 devices. Temperature sensors in the chassis monitor the temperature within the chassis. Wait for the power supply LEDs to fade out and for the fans inside the power supply to shutdown. MX80 router—Replace fpc-slot with a value from 0 through 1. M120 routers only—Replace slot-number with a value from 0 through 5. Hardware serial identifier of the QFabric system component. This chapter explains the content of the output fields, which appear in the output of most show interfaces commands. In this unit we will dig more about the “show” command. QLogic Fibre Channel Switch CLI Commands. Description. 1 up up inet 172. node. In many occasions through this course, I have used the “show” command to check if the things that I was configuring was correct. Radware Alteon OS CLI Commands. Note: PEM with no feeds connected at bootup on MX10004 and MX10008 devices, continues to stay in "Present" state until feeds are connected to it. Physically connect the two devices together to form the control and fabric (data) links. Neighbor List ID Interface. Maximum transmission unit size on the physical F4 and F5 are top level faults, where F4 is affected by F1, F2, and F3; and F3 is affected by F1 and F2. TPM can be owned even if the Master Encryption Key and Master Encryption Key are not created/configured. (Optional) Display chassis environmental information for the specified Routing Engine. Monitoring using the “show” command on Juniper. Table 1: show vrrp Output Fields. Otherwise, replace slot-number with a value from 0 through 31. Role of the member router in the Virtual Chassis: Master or Backup. Release Information. Index number of the physical interface, which reflects its initialization sequence. Once both nodes are powered up, run the show chassis cluster status command again . Off. RPF Failures Field. State of the physical interface. Customers can use winscp (or similar software) to copy from windows desktop to SRX. The Junos OS command-line interface (CLI) is the primary tool for controlling and troubleshooting firewall hardware, Junos OS, routing protocols, and network connectivity. System status word, a code representing the status items listed. ix. Output fields are listed in the approximate order in which they appear. Figure 1: Chassis Status LEDs in EX4650. (EX4200 switches and MX Series routers only) (Optional) Display system storage statistics for the specified member of the Virtual Chassis configuration. Specifies whether TPM is enabled or disabled. The output fields are listed in the approximate order in which they appear. M120 router—Replace slot with a value from 0 through 5. 1 and later, alarms for fans also show the slot number of the malfunctioning fans in the CLI output. Junos OS generates system log messages (also called syslog messages) to record events that occur on the device, including the following: Routine operations, such as creation of an Open Shortest Path First ( OSPF) protocol adjacency or a user login to the configuration database. The state can be one of the following conditions: Dead —Held in reset because of errors. Table 1 lists the output fields for the show system visibility cpu command. For an MX Series Virtual Chassis, replace member-id with a value of 0 or 1. On other switches, indicates that the Routing Engine is operational. user@host# edit interfaces. If a device type is specified, display logs for a device of that type. Jul 18, 2012 · Show commands can be executed from any level of router mode. Slot number and state. Dormant —Held in reset. gz root@device_name:/var/tmp. Displaying Users Currently Editing the Configuration. Report a Security Vulnerability. Specify either the device ID or the device alias (if configured). 254/24 irb. Routing Engine is functioning normally. Table 1 lists the output fields for the show chassis adc command. Routing Engine has failed. Other options could be leap_add_sec, leap_del_sec, or leap_alarm, indicating a leap second will be added, deleted, or a show interfaces extensive (EX4400-48T, EX4400-48P, EX4400-24T, EX4400-24P) Starting in Junos OS Release 21. status. SNMP index number for the physical interface. A third-party optic is a part, such as SFP, QSFP, QFSP+, or a cable such as DAC, which is not supplied by Juniper but used by the customer or partner on Juniper Hardware. Common Output Fields Description. Redundancy Group—ID number (0 - 255) of a redundancy group in the cluster. Maybe Later. Chassis status LEDs. Apr 26, 2002 · Table 1 lists the output fields for the show interfaces (logical tunnel) command. EX4650 switches have four chassis status LEDs (labeled ALM, SYS, MST, and ID) (see Figure 1 ). Use this guide to install hardware and perform initial software configuration, routine maintenance, and troubleshooting for the MX960 5G Universal Routing Platform. Policer Field. The LEDs, labeled MASTER, HDD, ONLINE, and FAIL, are located directly on the faceplate of the Routing Jul 2, 2012 · Prior to 11. Table 1: show chassis fpc Output Fields. Cluster and Redundancy Group information - Continue with Step 2. 1X45-D10. For information about the options, see show chassis environment routing-engine. Apr 13, 2018 · To check the PIC media type and status for a particular FPC, use the show chassis fpc pic-status fpc-slot command. Unique number for use by Juniper Networks technical support only. Name of the physical interface. Mar 22, 2011 · Yes - Both nodes are powered on. 22. Routing Engine is transitioning online. Overview. Turn off power to where the AC line goes into the power distribution module (PDM) area. This is an example of the Hardware Counters for Interface ethernet 1 . Type the following to check the status of the HA LED: SRX# run show chassis cluster information | match "Current LED color". PoE available in all RJ-45 ports in EX3400-24P and EX3400-48P models. IP address and VPLS identifier for the VPLS neighbor. Platform component name. If you are in operation mode “#”, you will have to use the keyword “run” before show commands, as shown in following example. Total number of VRRP groups configured on the interface. Table 1 lists the output fields for the show chassis cluster information command. These explanations can also be viewed by clicking the Help '?' icon in the upper right corner of the WebUI. Total number of VRRP groups that are active (that is, whose interface state is either up or down). Open —Port is not connected (Equivalent to Detection in Progress). 0 up up inet 172. EX4300-48MP and EX4300-48MP-S switches have three chassis status LEDs (labeled ALM, SYS, and MST) on the right of the front panel (see Figure 2 ). Probed—Probe is complete; awaiting restart of the Packet Forwarding Engine Routing Engine is the Primary. The output also states either Hardware Not Supported or Hardware Not in Right Slot. The nodes of the SRX chassis cluster are in primary and disabled states. Health parameter name. Control link: On the SRX240 device, connect ge-0/0/1 on device A to ge-0/0/1 on device B. Target will be FPC0, 1, 219. These LEDs indicate the status of the network ports. Peer ICD Conn State—Status of ICD. Online —The adapter card is online and running. About This Guide. fpc-slot slot-number. Online —FPC is online and running. Diag —Slot is being ignored while the device is running diagnostics. misconfig —the cascade port is assigned, but this interface is not working correctly due to a misconfiguration. The FPC is coming up but not yet online. Displays the TPM’s Master Binding Key status whether it is created or not created. Total number of CPUs. online. Uplink failure detection allows switches to monitor uplink interfaces to spot link failures. Table 1: show ntp status Output Fields. Explore by Category Explore by Product. For EX4200 switches, replace member-id with a value from 0 through 9. ID number (1-255) is applicable for Releases 12. When you configure BGP neighbor discovery through RPM, the output for this field is Rpm-Bgp-Owner. Protocol configured on the interface. There only exist a Command "show ethernet-switching interface" (without "s"), and the output is tottaly different. Physical interface index number, which reflects its initialization sequence. Offline —Adapter card is powered down. Operational mode CLI commands enable you to monitor and control the operation of a Juniper Networks device. filename. You toggle the status LEDs to show the different port parameters for the We would like to show you a description here but the site won’t allow us. configure—To enter configuration mode. When a network is loaded, the Hardware Inventory window can be opened by selecting Inventory > Hardware Inventory . Type. Also check that all the FPC's are showing online before proceeding to check the above command. Table 1 describes the chassis status LEDs on an EX4300 switch, their colors and states, and the status they indicate. State of the health parameter. Move the power switch on the power supply to the off (o) position. Encapsulation being used on the physical interface. Field Name. Each Routing Engine has four LEDs that indicate its status. We can see whether an SFP is NEBS compliant or not by using show sfp <index> from the shell of the FPC. Label-Switched Interface Traffic Statistics Field. Hostname: R1-MX960-re0. This command is not supported on FPC slot 0. For the routing matrix, the filename must include the chassis information. Power required and measured on the fan tray. Once the hardware target is determined, ask the hardware for the index assigned to the SFP or SFP+ you want to look at. EX4600 Quick Start. 254/24 May 16, 2020 · If we have an interface card inserted into the FPC slot on an SRX branch device (say SRX340), the output of show chassis fpc displays CPU less FPC . Default threshold value for the health parameter. MX240 router—Replace fpc-slot with a Release Information. Upload the 'offline-update. We would like to show you a description here but the site won’t allow us. For example using SCP: scp offline-update. MX104—Replace fpc-slot with the value from 0 through 2. ID number (1-15) of a cluster is applicable for releases upto Junos OS Release 12. CAUTION: Jun 5, 2020 · However, users may see MIC 0/0 port status on an MX5 that was delivered to them as an RMA replacement part. The asterisk ( * ) following the Role denotes the router on which the show virtual-chassis status command was issued. This article demonstrates such a scenario and clarifies that no action would be required and that the device can be used as expected. Bring the MIC online. For QFX5700 with Junos OS Evolved, details about CPU and memory utilization are also displayed for RCB slot 0 and slot 1. You can view the colors of the three LEDs remotely through the CLI by issuing the To enable a physical interface: In configuration mode, go to the [edit interfaces] hierarchy level. 3at standard, which can be enabled for high or ultra-high power delivery: Enabled —High or ultra-high power mode is enabled. routing-engine re-slot-number. user@host> #comment-string. lab@R1-MX960-re0 > show version. Master LED: Displays status of the MST LED (on EX3200, EX4200, and EX8200 switches): Green—On an EX4200 Virtual Chassis switch, indicates the switch is the primary in the Virtual Chassis configuration. Oct 21, 2022 · Description. Starting in Junos OS Release 22. The lowest level (leaf) faults, F1, F2, and F5, have no affected events. Oct 13, 2009 · Configuration. comment-string is the text of the comment. 17. The alarm indicates that the source FPC is running with a degraded fabric condition. . 1. Filters Field. Table 1 lists the output fields for the show chassis fabric device command. Member IDs and Virtual Chassis port interfaces (in the format vcp-slot/pic/port) to which this member router is connected. Mar 13, 2024 · Once you have selected the target version, you may run the following commands before and after the upgrade to compare outputs: show version (check OS version) show chassis routing-engine (check RE status) show chassis alarms (check hardware alarms) show systems alarms (check system alarms) Apr 26, 2002 · Table 1 lists the output fields for the show interfaces irb command. When viewing hardware information at a specific node, the Hardware Inventory window is split into two panes. MX480 router—Replace slot with a value from 0 through 5. This can take up to 10 seconds. Table 1 lists the output fields for the show chassis hardware command. MX5-T ( SN:XXXX ) does not show interface status of xe-0/0/*, and all xe-0/0/* port LEDs are Use show chassis satellite detail to gather more information on the issue when the device state is Miswire. gz' file. FPC slot number where the MIC is installed: ACX4000 router—Replace fpc-slot with the value 0 or 1. Name of the logical interface. The server that is connected to the disabled downlink interfaces triggers a network-adapter failover to a secondary link to avoid any information drop. For example, the following commands have the same result: user@host> show chassis pic fpc-slot 1 lcc 1 pic-slot 1 user@host> show chassis pic fpc-slot 9 pic-slot 1. This article provides information about Juniper support for third-party optics and cables on Juniper platforms. 1R3-S6. 1R1, the CPU allocations are displayed as a number range (for example, 4-7) instead of individual numbers (for example, 4,5,6,7). Current State—State of the redundancy group: primary Table 1 lists the output fields for the show system inventory hardware cpu command. Do you see node0 and node1 listed under Redundancy Group 0? Yes - Continue with Step 3. Field Description. Source Class Field. Protocol Field. 1R1, the 1Gbps or 100Mpbs port switches to low power idle (LPI) mode based on the following conditions: When a port operates at 1 Gbps speed and no traffic is either received or transmitted, then the port enters LPI mode. Role. Output Fields. For all other Junos OS Evolved platforms, use the show system errors active, show system errors We would like to show you a description here but the site won’t allow us. 1F6, 16. Values include qfxc08-3008 (QFX3008-I Interconnect device), qfx3600-I Table 1 lists the output fields for the show security tpm status command. Use this guide to install hardware and perform initial software configuration, routine maintenance, and troubleshooting for the EX4600 switch. Number of the PEM slot. EX4100 switches have network port mode LEDs (labeled SPD , DX, EN, and POE ) on the right side of the front panel (see Figure 8 ). 0. leap_none. QFX5100 Device Models. Field Dec 12, 2012 · To do this, run the command ' show interfaces terse irb ' command to verify the status of an IRB interface: user@router> show interfaces terse irb* Interface Admin Link Proto Local Remote irb up up irb. Apr 23, 2019 · Table 1: show chassis environment pem Output Fields. If any one of the following conditions are true on the remote PE router's CE facing link, the psuedowire is brought UP; otherwise it is brought down as RD on the local PE. The hardware counters provide the following information. Dec 4, 2023 · Solution. Status of four-pair PoE (PoE-4P), a Juniper Networks extension to the IEEE 802. Command introduced before Junos OS Release 7. Chassis Status LEDs on a QFX5100 Device | 49. 2. (Optional) Display the log messages in the specified log file. Model number of the QFabric system component. —. No - Power on the device (node that is in lost state) and proceed to Step 3. M120 router—Replace fpc-slot with a value from 0 through 5. Also displays information about Flexible PIC Concentrators (FPCs) and associated Physical Interface Cards (PICs Table 1: show services rpm probe-results Output Fields. Temperature in Celsius (C) and Fahrenheit (F) maintained by the fans. FourPair status. Status of the adapter card. What output do you see? C hassis cluster is not enabled - Consult KB15650. In addition to configure, to display the contents under a configuration hierarchy, user should have the required privilege level to view the configuration under that configuration hierarchy. down —the cascade port is down. Understanding Hardware Redundancy of QFX5100 Device Components and Functionality. 1R1, and later releases. Owner name. This also not exists on EX4550. present —The cascade port recognized the satellite device and is up. Present—FPC is detected by the chassis daemon but either is not supported by the current version of Junos OS or is inserted in the wrong slot. These are both stored in the same table: Yes. Sep 3, 2018 · This article explains how to check whether an SFP+ is NEBS compliant or not by using show sfp <index> from the shell of the FPC. For example on a ge-5/0/1 interface: user@host# show ge-5/0/1. Users may find that the physical interface in a Juniper Networks EX or QFX Series Switch is not listed in the show interface command output. gz' file to the SRX device. Type of connection: loc (local) or rmt (remote). 1. State of the interface. 113. PEM slot status. Table 1 lists the output fields for the show chassis environment fan command. Display diagnostics data, warnings, and alarms for Gigabit Ethernet, 10-Gigabit Ethernet, 40-Gigabit Ethernet, 100-Gigabit Ethernet, or Virtual Chassis port interfaces. When you configure the probe owner statement at the [edit services rpm] hierarchy level, this field displays the configured owner name. Installing a PSU into an EX4400 model which is not supported by the platform results in the switch not reading the PEM info properly. Also the XML-Output on EX4300 have a prefix like this "l2ng-l2ald" / "l2iff". Junos Static Routing Configuration Examples. This window contains reports and information about the hardware at each individual node in the network. Interface—Interface used for ICD. Table 1 lists the output fields for the show chassis high-availability information command. Proceed to Step 4. Use the mode button on the right side of the front panel to toggle the status LEDs. Jan 21, 2004 · From the ScreenOS options menu, click Reports , select Counters , and then click Hardware . Indicates a normal synchronized state with no leap seconds imminent. Note: Nov 15, 2017 · user@host> show chassis environment pem PEM 0 status: State Online Temperature OK 34 degrees C / 93 degrees F AC Input OK 118 Volts DC Output Voltage(V) Current(A) Power(W) Load(%) 12 11 132 11 PEM 1 status: State Online Temperature OK 29 degrees C / 84 degrees F AC Input OK 119 Volts DC Output Voltage(V) Current(A) Power(W) Load(%) 12 10 120 10 Table 1 lists the output fields for the show system health-monitor command. QFX5100 Power System | 53. Cold Sync Status—cold sync status of the node. State of the interface: Enabled or Disabled. Possible values are described in the “Enabled Field” section under Common Output Fields Description. Start here to evaluate, install, or use the Juniper Networks® SRX240 Services Gateway, a small network firewall with 16 10/100/1000 Ethernet LAN ports and 4 Mini-PIM slots. Status of the PEM. The operational mode commands exist in a hierarchical structure. member member-id. PoE not available in any network port Table 1: show interfaces smart-sfp-defects Output Fields. 144 (vpls-id 200). When a switch detects a link failure, it automatically disables the downlink interfaces in that group. 13. Current LED color: Green. You can view the colors of the three LEDs remotely through the May 26, 2023 · Additionally, the switch does not report the presence of the installed unsupported PSU in 'show chassis hardware' while showing PSU status OK for the unit ('show chassis environment'). After completing the installation and basic configuration procedures covered in this guide, refer to the Junos OS documentation for information about further software configuration. System Log Overview. CLI commands display information from routing tables, information specific to routing protocols, and information about network connectivity derived from the ping and Dec 24, 2017 · Browse the URL using IE/Firefox/Chrome: It will download 'offline-update. kh qj iy tx py ei eg fa ri sm