logo logo

Oleobject powerbuilder

Your Choice. Your Community. Your Platform.

  • shape
  • shape
  • shape
hero image


  • Symptom When using the Dec 18, 2014 · Using my dll as OLE Object in Powerbuilder. An OLEControl placed in a window can contain an object, such as a spreadsheet or word processing document, that was created. If the object doesn’t need to be visible in your PowerBu Mar 20, 2019 · Hello, We are using Web Browser in a OLE. PowerBuilder provides several functions for changing the object in an OLE control. I have a simple window with a command button on it. Code a messagebox in the externalexception event of the nvo. The band containing the OLE Object control. For more information about OLE information in the Browser, see “OLE information in the Browser “. I have an application which has a blob column OLE_OBJ and a varchar column OLE_FileName. Jul 10, 2020 · PowerBuilder. Boolean. 2. silent=1. A DWObject reference allows you to refer directly to controls within a DataWindow. Feb 4, 2015 · I have created an OLE object in a window of Powerbuilder. If objectname is null, TypeOf returns null. Now we want to convert these blob to files, files are of different format(PDF, JPG,EXCEL,TEXT,DOC) There are more than 1 Million files so it is not easy to do manually open and save using olecontrol. Save() In a window’s Open script, this code creates a storage variable. CheckBox. to a COM object that is registered on a local or remote computer. Other PowerBuilder applications will be able to open the objects in a storage file built by PowerBuilder. Application") s_ie = IE. classname (optional) A string whose value is the name of an OLE class, which identifies an OLE server application and a type of object that the server can manipulate via OLE. Oct 1, 2003 · HI, I'm using PB OLEObject to dynamically declare and connect to an OCX file. Aug 13, 2023 · The OLEObject variable can be used for automation, in which. disconnectobject() DESTROY Nov 13, 2002 · Here is a quick example that opens an XLS file and saves it as a CSV fileGood Luck. You can also call the Activate function to activate the object in a script. Then under the ‘Common Items’, choose ‘Interface’. You can use a DWObject variable to simplify DataWindow property and data expressions. PowerBuilder. ole_1. Setting up the OLE control. The function you choose depends on whether you want the user to choose an object and whether the object should be linked or embedded, as shown in Table 19-2. Hoping to get an answer asap. I need to make an HTTP POST call from POWERBUILDER 12. dw_1. user can activate the object and edit it in the application in which. ConnectToNewObject("PNSrv9. PNSession") if ll_status = 0 then // Set the session printer try . for example from :tali@gmail. The object column is a blob datatype and contains OLE objects associated OLE DB API. Graph controls in windows and user objects, and graphs in DataWindow controls and DataStores. visible = true lole_excel. //1. An internal pointer. In order to support OLE, OLEObject is a dynamic object. This will bring up the window to select the type of OLE object you want to embedd on the window. Aug 21, 2023 · PowerBuilder provides several functions for changing the object in an OLE control. 3. It is possible the events you need are available on your OLE object but I don't know for sure, have never done it that way. //3. Syntax. Select Insert>Control>OLE Object from the menu bar, or from the toolbar, click the Object drop-down arrow and select the OLE button (not OLE Database Blob). lole_excel = CREATE OLEObject. The Application object defines application-level behavior, such as which fonts are used by default for text, and what processing should occur when Mar 2, 2012 · Have you tried using the . I can access the functions just fine after I call 'OLE. I am facing a difficult problem. In main menu select Insert>Control>OLE so the Insert Object window appears. It must contain at least two columns, id and object: The id column is an integer and serves as the table's key. result = lole_excel. 5 , below is the steps I have done: - I registred the mscomm32. In Windows Explorer, right-click on this file and select the Details tab to see the product version. Object. Dec 7, 2022 · Notwithstanding Miguel's reply for the moment (and he does have a valid point to take into consideration), yes, you can change this setting in the Registry. Aug 3, 2023 · OLE object category Description; Insertable objects: OLE servers that can link or embed objects in OLE containers. Fullname () Run (s_ie + "" + s_url) The problem is that I am not satisfied with this solution. Mar 4, 2010 · Saving Ole objects in powerbuilder. Permalink. Click the OLE tab in the Browser. Syntax 5: For opening an OLE object in a file into an OLEStorage. integer result. My question is how will we know which version of IE is running in PowerBuilder OLE? Is there a way to register which version of IE we would like to use within our OLE object? Let say later version of IE or if we can make use of Microsoft Edge will be great. application. PowerBuilder reads the registry and displays the registration information for all registered OLE servers and custom controls. Whether the control can be embedded, linked, or both. not have an OLE object assigned to it). insertfile (as_filename) I have the DisplayType set to "Displayascontent!" This will load the excel file's first tab/page into the control, but I cannot see any other tab or pages as there is not scroll capability Select Insert>Control>OLE Object from the menu bar, or from the toolbar, click the Object drop-down arrow and select the OLE button ( not OLE Database Blob). This allows you to call methods and set Open the DataWindow object that will contain the OLE object. The function you choose depends on whether you want the user to choose an object and whether the object should be linked or embedded, as shown in the following table. IsDragTarget. Saving as a PSR You can save the object with its data by saving the DataWindow object as a Powersoft report (PSR). I can't give you the exact PB syntax, but I can give you the Word object model syntax, which you shouldn't have any difficulty "translating". It can also be used to connect. Open any or create a new workspace, and then open any window in layout mode. ocx - Created OLE object control and dropped it in a window - Under button, I put te below code ole_1. exe, you can use these commands: If you are using RegAsm. I want to open a Web page in object "Window" in PB. CreateItem (0)lole_msg. //4. From the Project menu, choose ‘Add New Item’. ole_stor, which is declared as an instance variable, and associates it. from - this is not working PB2019 the send and mail is ok but the "from" user is the current machine us Oct 28, 2015 · From the research I have done, it sounds like PB may expect the ole object to provide the menus and toolbars, but my PB menu items are unaffected, it is just the toolbar. PowerBuilder global functions in powerscript. Let the user choose an object and, if the control’s Contents property is set to Any, whether to link or Syntax 1: For windows of a known datatype. SaveAs ( { filename, } { graphcontrol, saveastype, colheading { , encoding } } ) Argument. connectToNewObject("InternetExplorer. OLE servers that support insertable objects must have a visual component: Custom controls: ActiveX controls that can be included in an OLE containerActiveX controls can also be insertable objects. Create Excel Object. navigate ("www. There are three categories of OLE object, as shown in the following table. Each column, computed field, text control, or drawing control is a DWObject. 5 by calling up the browser. Dec 17, 2007 · I'm trying to do a find and replace using the oleobject connected to a word document. In the code for the interface, replace it with the following: VB. // Create or "Instantiate" the ole_object variable. specified control. Mar 1, 2015 · I have saved data in format of blob using powerbuilder ole control in oracle. Internet Explorer are all working properly. Instead of using an oleobject variable create a PowerBuilder standard class non-visual object (nvo) of type oleobject: 2. index can be either the position in the document (the n th form field in the text) or the name of the form field as a string ("Check1" for The Application object is the entry point into an application. ( Which will be determined by OLE_FileName). To view the OLE information: Click the Browser button on the PowerBar. silent=1 before navigate (). ole_1. MessageBox("Value = ", +String(li_rc)) IF li_rc <> 0 THEN DESTROY ole_3 END IF. Application") Aug 10, 2021 · PowerBuilder. If you omit classname, PowerBuilder uses the extension of filename to Aug 21, 2023 · Syntax 1: For OLE controls. I am using an OLE Control to view an Excel Document in my application. or that is installed in COM+. Although Excel, Word, and other server applications store their native data in OLE storages, these files have their own special formats, and it is not PowerBuilder provides access to storages and streams with the OLEStorage and OLEStream object types. ConnectToNewObject("excel. ConnectToNewObject ("excel. Syntax 4: For opening an OLE object in memory into a control. // connect to C# class. If so, they will appear on both lists The OLEObject variable can be used for automation, in which the PowerBuilder application asks the server application to manipulate the OLE object programmatically. Subject = as_subject lole_msg. open(file_name) lole_excel. Jan 12, 2015 · Let me know if you need clarifications but if you research inet, internetobject I think you will figure it out. May 24, 2013 · It's and ancestor problem, try to regenerate all PBLs. Applies to. Aug 3, 2023 · Programmable OLE Objects . You specify what is allowed in the control by setting PowerBuilder properties. ConnectToObject. Doesn't this also mean that the OLE object is disconnecting? Question 2: If I do not destroy a dynamically created OLEObject variable, does it cause a memory leak or does PowerBuilder's Aug 3, 2023 · The OLE control contains an insertable OLE object. ConnecttoNewObject()' but I Dynamic OLE Object Events - Sybase: PowerBuilder - Tek-Tips The OLEObject variable can be used for automation, in which the PowerBuilder application asks the server application to manipulate the OLE object programmatically. Click where you want to place the OLE object. appeon. To activate the OLE object in the container in the Design view: Select Open from the container’s pop-up menu. 1. This makes me believe that the server app is being halted. IF ole_object. Associates an OLE object with a PowerBuilder OLEObject variable and starts the server application. Step 1. by an OLE-aware application. The PowerBuilder class OLECustomControl is a container for OLE custom controls, also known as ActiveX controls or OCXs. OLEObject object type. Syntax 2: For windows of unknown datatype. Previewing an OLE column. OLEObject is a dynamic object. ole_object. Use TypeOf to determine the type of a selected or dragged control. OLEObject object. On July 5, 2016, SAP and Appeon entered into an agreement whereby Appeon, an independent company, would be responsible for developing, selling, and supporting PowerBuilder. FALSE – OLE object cannot be dropped on control. Aug 3, 2023 · For custom controls and programmable OLE objects, you can see a list of properties and methods in the PowerBuilder Browser. Aug 3, 2023 · in your PowerBuilder application, you can create an OLE object independent of a control, connect to the server application, and call functions and set properties for that object. Values are: TRUE – OLE object can be dropped on control. You might never need to use PowerBuilder’s storage When you compile it as a 64-bit application, it cannot call the 32-bit OLE object/control. Contribute to pabloae/PowerBuilder-Functions development by creating an account on GitHub. In PowerBuilder, an OLEObject is your interface to an OLE server or ActiveX control. I did an article on how to do that using PBNI for the PowerBuilder Developer's Journal (PBDJ) back in 2006 (based on a code sample I did back in 2003). PowerBuilder XML Document Parse Using PBDOM OR OleObject PowerBuilder XML Document Parse Using PBDOM OR OleObject. With the window painter open, select the OLE object. A DataWindow property expression uses the Object property of the DataWindow control to access the DataWindow object. l_ole_ie = create OLEObject. This chapter describes how to use OLE in DataWindow objects. PowerBuilder is an integrated development environment owned by SAP since the acquisition of Sybase in 2010. String (Read-only) The entire link name of the item to which the object is linked. Specifies whether an OLE object can be dropped on the control. The name of the object or control for which you want the type. This section describes how to create an OLE column in a DataWindow object. Before using the DataWindow object in an application, you should preview it in the Preview view or in preview mode to see how it works. Object property. In PowerBuilder, the OLE control is a container for an OLE object. Displays a standard OLE dialog allowing the user to choose whether. ConnectToNewObject ("InternetExplorer. [1] Reproducing the Issue. It can also be used to connect to a COM object that is registered on a local or remote computer or that is installed in COM+. I am using PowerBuilder version 11. //2. If you want the user to choose the OLE object, you can write a script that calls the InsertObject function. Friday, 10 July 2020 15:56 PM UTC. My control does contain a toolbar (the control is a rich text editor I created to workaround some shortcomings of the built in control) but I have also tried creating a new Jul 11, 2005 · Some times when the user does "multi-stress clicking ;)" (clicking more than once without wait to load the page) the accessing ole object craches. it was created (the server application). Value = true 'or false. The user can activate the control and edit the object using functionality supplied by the server application. Add a new workbook. result = olestor_1. user2456249. A PowerBuilder DWObject object is an object that exists within a DataWindow object. To preview an OLE column in preview mode. Application. Generally, the OLE control is set so that the user can activate the object by double-clicking. The OLEObject variable and ConnectToObject are used for OLE automation, in which the PowerBuilder application asks the server application to manipulate the OLE object programmatically. function, and linking is the same as calling PasteLink. You can change the object in the control in the painter or in a script. In this window, the InprocServer32 entry under "Class Information" will show you the file path. The PowerBuilder compiler acceps property names and function names and parameter lists that are not already defined for the object. PowerBuilder’s OLEObject object type is designed for automation. PowerBuilder DataWindow/DataStore/DataWindowChild (except for Composite, Crosstab, OLE 2. When you define OLE controls and OLEObject variables, you have full access to the functionality of server applications and automation, which already provide you with much of OLE’s power. You can customize your own version of the OLEObject object by defining a standard class user object inherited from the built-in OLEObject. PowerScript. 5. The OLE_OBJ can contain any type of file xls, pdf, jpg etc etc. The OLEObject object acts as a proxy for a remote OLE object. Object enumerated datatype. The OLEObject variable can be used for automation, in which the PowerBuilder application asks the server application to manipulate the OLE object programmatically. Jan 19, 2016 · 0. A list of the properties of the OLE Object control. Sep 8, 2015 · If you run a website in an external application, eg. OLE DB is a standard application programming interface (API) developed by Microsoft. You don’t need to place an OLE control on a window to manipulate an OLE object in a script. OLEObject is a dynamic object type, which means that the compiler will accept any property names, function names, and parameter lists for the object. There are three categories of OLE object, as shown in Table 19-8. Users can create their own session objects using the exported data source object, so they can get a new independent connection that has connection properties similar to those used by PowerBuilder OLE DB. Description. LinkItem. The PowerBuilder compiler accept property names and function names and parameter lists that are not already defined for the object. ole_object = CREATE OLEObject. The values from this column (OLE_OBJ) are retrieved on the Powerbuilder screen. CommPort = 1 Instead of using an oleobject variable create a PowerBuilder standard class non-visual object (nvo) of type oleobject: 2. The script. The steps are illustrated using a table that you can create in the Database painter. If I understand what you want to do, they you need to create your own COM object that is an event sink for the OLE object that you are creating. Code snippet below: ole_1. Click the Insert Row button. The instruction might be a property whose value you want to get or set, or a function you want to call. Code is written below and it is crashing. doc" string ls_null setnull(ls_null) Step 2: Install the OLE DB interface and data provider. to embed or link the OLE object on the clipboard when pasting it in the. Open the specified workbook. 8") = 0 THEN. application") IF result < 0 THEN DESTROY lole_excel MessageBox("Connecting to OLE excel Object Failed","Error: " + String(result)) Return ELSE lole_excel. PowerBuilder OLE DB can export OLE DB data source objects or session objects to users using the PowerScript function DBHandle. Syntax 1: For graph objects. OLE object category. with a storage file that contains several Visio drawings. If your PDF browser ActiveX control is outdated, it maybe cannot Jul 22, 2003 · OLEObject lole_excel. When you create an OLE control and insert an object, PowerBuilder activates the Jul 26, 2019 · 0. OLE data is stored in objects called streams, which live in objects called storages. Following the Object property, you specify a control name and one or more properties. Syntax 3: For loading an OLE object from a file into a control. From then on, the server services the data: updating it, saving it back to the data file, updating information about the item (for example, remembering that you inserted a row in the middle of the range of linked rows). com") This will not eliminate the root cause of the javascript errors, the additional line of code just suppresses the errors. Can we do it through script auto saving of blob to file in powerbuilder The syntax of a property expression allows you to address any of these properties. Specifies the height of the control, in PowerBuilder units. OLE servers might be either DLLs or separate EXE files. OLEObject l_ole_ie. Information in the OLE object tells PowerBuilder what server to start and what data file and item within the file to use. The simple syntax is: Aug 3, 2023 · In addition to OLE objects in controls and objects for automation, PowerBuilder provides an interface to the underpinnings of OLE data storage. To use the Insert Object dialog box, see “Defining the OLE object”. li_ReturnCode = l_ole_ie. object. OLEObject objects. OLEObject is a dynamic object In order to support OLE, OLEObject is a dynamic object. The way the OLE Object control is activated. PowerBuilder displays the Insert Object dialog box. Oleobject is connected to the active object in the server application specified in classname. This section discusses OLE storage files that a PowerBuilder application has built. Select File>Save As File or File>Save Rows As from the menu bar. It is a discrete object that is saved in a PowerBuilder library (PBL file), just like a window, menu, function, or DataWindow object. PowerBuilder's OLEObject object type is designed for automation. Embedding is the equivalent of calling the Paste. hi what is the way to define "from" in outlook application message. Usage. LinkTo( pdf_link ) Jun 22, 2012 · The last thing we need to do in Visual Studio is to add an Interface to the project so the events we are exposing can be seen from within PowerBuilder. PowerBuilder does not have to know whether the properties and functions are valid. Firstly, you need to use 64-bit registering tool to register the OLE object/control: If you are using regsvr32. Any leads, answers and solutions will be greatly appreciated. Object for the OLE object itself? For instance, using your example, it would look like: w_datawindow_drawing. If that doesn't work, then probably the function in one of the main PBLs was deleted by accident or the PBL is corrupted, in that case, you should have a back-up PBL. ole_excel. About this chapter. Sep 2, 2011 · OLEObject PNSession PNSession = CREATE OLEObject ll_status = PNSession. OLEControl control. Return value. exe, you can use these commands: Secondly, add a blank OLE control (without Aug 4, 2021 · Page : 1. It is a component of Microsoft's Data Access Components software. If the object in the control is linked and the linked file is missing, the user cannot activate the control. DisplayAlerts = "False". Is oleobject slow?? Why it crashes? How can i check when the page is loaded??? I tried to include the Active X Control IE Browser in a pb window but by default the OCX use Microsoft VM but i need Sun VM. Select File>Run/Preview from the menu bar and select the DataWindow object. Solution. The OLETxnObject variable is used to provide COM+ Oct 29, 2020 · Highlight one, then click the Browse button to see the OLE Object Browser window. If the Update property is set to Automatic, PowerBuilder displays a dialog box PowerBuilder reads the registry and displays the registration information for all registered OLE servers and custom controls. (exp) The type of border around the OLE Object control. Cause. It provides an application with uniform access to data stored in diverse formats, such Apr 11, 2005 · I'm trying to send a string to certain port using OLE object using powerbuilder 11. the OLE object programmatically. # 3. When you create a PowerBuilder OLE custom control container, the Insert Object dialog prompts you to select the control to insert in the container. The key is HKEY_CURRENT_USER\SOFTWARE\Adobe\Adobe Acrobat\DC\AVDisplay and the value name is iPDFAPolicy (your exact key may differ depending on version etc. The PowerBuilder application’s. Syntax 1: For windows of a known datatype. OLEObject ole_object. Jan 8, 2022 · Operation OLEObject Excel Command Powerbuilder. objectname. In the PowerBuilder Setup program, select the Custom install and select the OLE DB provider that accesses your database. controlname. ). The URL contains the server name as well as the data also. 0, and RichText styles) can exchange JSON data with RESTFul Web services. To suppress the javascript errors in your PowerBuilder application, use ole_1. FormFields(index). Aug 21, 2023 · PowerBuilder. Its working fine but I do not want to send the data via URL. Streams and storages are analogous to the files and directories of a file system. Set the third worksheet as the active worksheet. For more information, see “Activating OLE objects”. When you declare an OLEObject variable and connect to a server, you can use dot notation for that variable and send instructions to the server. workbooks. OLE DB allows an application to access a variety of data for which OLE DB data providers exist. answered Jun 5, 2013 at 15:00. Returns the type of objectname. Your choices are the controls that have been registered in the system registry. oDocument. Scroll down on the "Create New" tab until you see "Windows Media Player", and select it, and then click the "OK" button. Thanks Sep 15, 2008 · Date: Sep 15, 2008. It is created to generate a report on the data sent from Powerbuilder. I wrote this code opens the browser but does not pass the parameters of the post call. com Oleobject lole_msg lole_msg = CREATE OLEObject lole_msg = lole_session. Saves the data in a graph in the format you specify. Thanks, Tina-----oleobject ole_object1 oleobject ole_wordfind integer result, li_rc string ls_file = "C:\No detainer letter. The name of the OLE client in the server window. Within this window, my code looks like this: OLEObject ole_3 ole_3 = CREATE OLEObject. Source Code w_main from window. the PowerBuilder application asks the server application to manipulate. Point is that I pass the values from Powerbuilder window to the Ole web browser control via URL. Click on Insert Control tab in this window and then PowerBuilder crashes. Help me I'm desperate. By Mar 19, 1999 · OLEObject goes out of scope, the server window is closed. You can also automate OLE interactions by programmatically activating the object and sending commands to the server. Then place it on the window. Example: IE = CREATE OLEObject IE. jp sm gy ls nx ss ls xn jp an