2 aluminum wire ampacity. Wire Size and Amp Ratings Below.

To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors. Application. 85/ft. Dec 8, 2021 · Based on the 2017 N. Aluminum types like RHW and THWN are rated 90A at 75°C and 100A at 90°C for RHW-2 and THWN-2. Outside Diameter: . 063 lbs per ft. Conductor: Compact stranded aluminum alloy 8000 series per ASTM B-801. Search Amazon for your Electrical Southwire Type SE, Style SER service entrance cable is primarily used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard; however, it may be used in all applications where Type SE cable is permitted. Here is the 1st chart, followed by the 2nd chart. Dec 1, 2023 · An aluminum wire ampacity chart can help you decide which wire you can use based on temperature. Standards : Ampacities based on National Electric Code, 2005 edition, section 310-15, 90°C wet or dry locations. 030 26. Sizes 1/0 AWG and larger are CT Rated. 79 476 135 150 150 May 18, 2023 · The ampacity of your aluminum wire should depend on the type of wire and your working purposes. For long conductor runs where voltage drop may be an It is recommended that design engineers desiring accurate ampacity data closely study the 1999 National Electrical Code, Articles 310-15 through 310-84. * To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition. The proper amperage is determined by the size of the wire, ambient temperature, number of wires installed together, the types and number of electrical devices The aluminum wire ampacity chart basically tells you how many amps can aluminum wires handle. 539 inches. *Data provided on this page is subject to change based on different manufacturers variances. Given the 42. Ampacity at 60°C (140°F) Ampacity at 75°C (167°F) Ampacity at 90°C (194°F) Maximum Allowable Amps at 75°C. PriorityWire. Shipping Cost Calculated at Checkout. Search Amazon for your Electrical May 18, 2023 · The ampacity of your aluminum wire should depend on the type of wire and your working purposes. 34 286 90 100 100 1-02alumg-ser 2 x 1 18 3 7 0. 388 lbs per ft Ampacity: 280 Amps at 90°C. The cable can be installed without pulling lubricant. 150 Amps. Check out our Copper to Aluminum wire size conversion chart. , Max: 10000 ft. Table of Contents May 18, 2023 · The ampacity of your aluminum wire should depend on the type of wire and your working purposes. 840 21. What Is #2 Aluminum Wire Rated For? On average, the aluminum wire in the 2 AWG gauge has an ampacity of 90A at an ambient air temperature of 75°C (167°F). APPLICATION: Triplex Service Drop Aluminum Conductor cable is designed for use to supply power from utility lines to the consumer weather head. 2-2-2 Conch Aluminum Triplex Overhead Service Drop Cable. McGrath. Insulation: USE-2 has abrasion, heat and moisture resistant cross-linked polyethylene insulation XLPE. Weight: 1. Table of Contents The aluminum wire ampacity chart basically tells you how many amps can aluminum wires handle. As long as you know the ambient temperature and the number of wires you will use in a cable or raceway, you can directly use the table values to buy your tools as needed. Cross-linked Polyethylene (XLPE) Insulation. Number of Strands: 18. Southwire #: 27290699. 746 inches Weight: 0. 38 Thermoset-Insulated Wires and Weight Ampacity** at 75°C The aluminum wire ampacity chart basically tells you how many amps can aluminum wires handle. Insulation is an abrasion, moisture, heat, and sunlight resistant black cross-linked polyethylene. Number of Strands: 7. 193 lbs per ft Ampacity: 175 Amps at 90°C. If you have aluminum (or copper-clad aluminum), it can carry 75A at 60 degrees C, 90A at 75 degrees C, and 100A at 90 May 18, 2023 · The ampacity of your aluminum wire should depend on the type of wire and your working purposes. 40 /ft. Additional information can be derived from AIEE, Paper Number 57-660: "The Calculation of the Temperature Rise and Load Capability of Cable Systems" by J. WIRE / CABLE TYPE: Insulated wire types like THHN/THWN-2, XHHW-2 and USE-2/RHH/RHW-2 have an insulation temperature rating of 90℃, and any temperature correction factors or ampacity adjustment factors can be applied For ambient temperatures other than 78°F - 86°F, or more than three current-carrying conductors in a raceway, cable or Earth, use the Advanced Wire Ampacity Calculator. 1 gauge wire diameter is 7. Our aluminum conductors come with polyethylene or Aluminum-alloy gives 6201-T81 gives AAAC higher resistance to corrosion than ACSR. Also, the maximum permitted amps on aluminum wires to stand at an average of 75°C. Aluminum AWG Wire Size. 831 21. 2 AWG XHHW-2 Aluminum Cable 600V. $1. 1 gauge wire is the first ‘non-negative or 0’ wire gauge. 220 inches. 4th Length. To order multiple lengths, simply enter the desired footage into the quantity fields. and 25 amperes for 10 AWG aluminum and copper-clad aluminum after any correction factors for ambient temperature. Ampacity: 500 Amps at 90°C. Understanding the ampacity of 2 AWG wire includes factors such as conductor material, temperature, and The wire size chart below shows allowable ampacities of insulated conductors rated up to and including 2000 Volts, 60°C through 90°C (140°F through 194°F), not more than three current-carrying conductors in raceway, cable, or earth (directly buried), based on ambient air temperature of 30°C (86°F). TelcoFlex® II; TelcoFlex® III Conductor: Compact stranded aluminum alloy 8000 series per ASTM B-801. Return to top of page Dec 1, 2023 · An aluminum wire ampacity chart can help you decide which wire you can use based on temperature. 600 V Aluminum Alloy Conductor, UL recognized cross-linked Polyethylene Insulated Wire. 055 inches Outside Diameter: 0. May 18, 2023 · The ampacity of your aluminum wire should depend on the type of wire and your working purposes. 39 /FT Sale 44% off. com. The wire size chart below shows allowable ampacities of insulated conductors rated up to and including 2000 Volts, 60°C through 90°C (140°F through 194°F), not more than three current-carrying conductors in raceway, cable, or earth (directly buried), based on ambient air temperature of 30°C (86°F). The aluminum wire ampacity chart includes the number of amps aluminum wires can accommodate based on the three different temperature ranges of 140°F (60°C), 167°F (75°C), and 194°F (90°C). Select a Gauge. H. 16. Search Amazon for your Electrical ALUMINUM BUILDING WIRE 1-800-945-5542 www. Each length will be delivered on its own spool. 4kV; MV-105 - 5kV/8kV-15kV; Aluminum MV-105, 15kV; MV Accessories; Airport Lighting Cable; Thermocouple Wire; Central Office Power Cable. Sold by the foot. 16 431 120 135 125 2/0-02alumg-r-ser 2 x 2/0 18 1 18 1. Copper. Individual Conductors Rated XHHW Jacket and Inner Conductors are Sunlight Resistant. 2-2-2-4 3E AL SERVICE ENTRANCE TYPE SER PVC JACKET 1000 FT. Then divide the total wattage by the voltage of the system, 110 or 220, and that will give you the expected current or amps. Contact Us. 060 inches. Table of Contents 2nd NEC 210. SRML Wire - 150°C/200°C; SF-2/SEW-2 Wire - 200°C; PTFE Wire - 200C; TGGT Wire - 250°C; MG Wire - 450°C/550°C; Medium Voltage Cable. Table of Contents For example, 3/0 AWG copper has an ampacity of 200 amps at 75℃, while 3/0 AWG aluminum has an ampacity of 155 amps at 75℃. 0000 (4/0) AWG. Specifications*: Size: 350 MCM Number of Strands: 35 Insulation Thickness: 0. When used as Type USE-2, conductors are suitable for use as underground service entrance conductors for direct burial at conductor temperatures not to exceed 90°C. Inches : 0. Standard Lead Time is 1 to 6 Business Days. Conductor: USE-2 conductor is a compact soft drawn bare 8000 series aluminum, with Class B stranding per ASTM. 90°C- XHHW-2 wet or dry locations. Ampacity is the maximum continuous current carrying capacity of a wire inside a cable or raceway. This takes into account correction factors for voltage drop, temperature and the number of current-carrying conductors. Outside Diameter: 1. 4. 016 25. 094 27. 16) Allowable Ampacities of Insulated Conductors Rated Up to and Including 2000 Volts, 60° through 90°C (140° through 194°F), Not More Than Three Current-Carrying Conductors in Raceway, Cable, or Earth (Directly Buried), Based on Ambient Temperature of 30°C (86°F). Min: 40 ft. For service at 600 volts or lower (phase to phase) at a conductor temperature of 90°C maximum for cross linked insulation or 75°C maximum for polyethylene insulation. UL recognized cross-linked polyethylene. Specifications*: Size: 2 AWG. MV-90 - 2. Outside Diameter: 0. AlumaFlex® Brand Aluminum Alloy (AA-8176) Conductor. 3rd Length. How Many Amps can 2 Gauge Wire Handle? 2AWG copper wire can handle 95A at 60 degrees C, 115A at 75 degrees C, and 130A at 90 degrees C. Wire Size and Amp Ratings Below. For older or more specialized types like TW and UF, the amp rating at 60°C is 75A. 80 339 100 115 110 1/0-02alumg-r-ser 2 x 1/0 18 2 7 1. 4 mm2 (1 AWG to mm2) cross-section or area. Alan Wire has an extensive collection of professional resources that can help you determine the best product for your needs. Search Amazon for your Electrical SKU: NNC1751X. 937 23. Availability: IN STOCK, MINIMUM ORDER QUANTITY 80FT. It is measured in amperes (amps). 080 inches. SE may be used in wet or dry above ground locations at temperatures not to exceed 90 The aluminum wire ampacity chart basically tells you how many amps can aluminum wires handle. Neher and M. 2 No. 60. Allowable Ampacity-Direct Burial: 160 Amps at 90°C. com Part Number Conductor Size Conductor Diameter Insulation Thickness Overall Diameter Net Weight Ampacity* 2 2 4 aluminum wire, 100 amp service entrance cable. 391 inches. Min Length: 1 FT. We continue to look toward the The aluminum wire ampacity chart basically tells you how many amps can aluminum wires handle. C. 973, Approx. Aluminum. H. Southwire #: 13102901. ALUMINUM BUILDING WIRE 1-800-945-5542 www. Table of Contents The wire size chart below shows allowable ampacities of insulated conductors rated up to and including 2000 Volts, 60°C through 90°C (140°F through 194°F), not more than three current-carrying conductors in raceway, cable, or earth (directly buried), based on ambient air temperature of 30°C (86°F). Search Amazon for your Electrical Table 310. Alumaflex® Brand Aluminum Alloy (AA-8176) Conductors. Weight lb/1000FT : 435 lbs, Ampacity at 90°C : 115 Amps, Ampacity in dwelling : 110 Amps. com STANDARDS: • UL 44 / CSA C22. 2-02alumg-r-ser 2 x 2 7 4 7 0. Search Amazon for your Electrical 2nd NEC 210. In Stock. Table of Contents Dec 1, 2023 · An aluminum wire ampacity chart can help you decide which wire you can use based on temperature. 2nd NEC 210. 16 table includes aluminum wire (or copper-clad aluminum wire) ampacities from 18 AWG to 2000 kcmil for all 3 temperatures. Price: $0. 2. Allowable Ampacity-In-Duct: 120 Amps at 90°C. Underground Service Entrance Cable. Specifications*: Size: 3/0 AWG Number of Strands: 18 Insulation Thickness: 0. D. Neutral Conductor-Size: 2 AWG. 180 Amps. Feb 7, 2022 · ALUMINUM XHHW -2 BUILDING WIRE PRODUCT FEATURES: Compact stranded 8000 Series aluminum alloy conductor. 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper; or 15 amperes for 12 AWG. High Temperature Wire. Price: $2. Wire Gauge Copper Aluminum; 60 °C 75 °C 90 °C 60 °C 75 °C 2nd NEC 210. 1 AWG wire amps (ampacity at 75°C): 130 amps. Southwire Type RHH or RHW-2 or USE-2 conductors are used with conduit as specified in the National Electrical Code. High Heat, Moisture, and Sunlight Resistant. Ampacity based on NEC ® Table 310. Specifications*: Size: 2/0 AWG. Min: 100 ft. Example: What is #2 AWG wire rated for? Just check the chart, and you will see that 2 AWG gauge aluminum wire has a 90A ampacity at a median 75°C (167°F) temperature. Availability: In stock. Max Length: 10000 FT. Type SE and Style SER Service Entrance Cable. 065 inches Outside Diameter: 0. 16) Allowable ampacities of insulated copper conductors rated up to and including 2000 Volts, 60°C through 90°C (140°F through 194°F), Not more than three current-carrying conductors in raceway, cable, or earth (directly buried), based on ambient temperature of 30°C (86°F). Search Amazon for your Electrical 2-2-2 Triplex URD Cable Specifications*: Phase Conductor-Size: 2 AWG. The aluminum wire ampacity chart basically tells you how many amps can aluminum wires handle. 11 263 90 100 100 2-02alumg-ser 2 x 2 7 2 7 0. $0. E. SPECIFICATIONS: • ASTM B398 Standard Specification for Aluminum-Alloy 6201-T81 and 6201-T83 Wire for Electrical Purposes • ASTM B399 Standard Specification for Concentric-Lay-Stranded, Aluminum Alloy 6201-T81 Conductors Table 1 – Weights and Measurements 2nd NEC 210. Search Amazon for your Electrical Chart showing the allowable wire ampacities of insulated conductors per NEC Table 310. Two, Three or four conductors can be paralleled on a reel. and number of conductors have been applied. 70. Specifications*: Size: 1000 MCM. 2 AWG XHHW-2 Aluminum Building Wire. . Number of Strands: 58. Search Amazon for your Electrical Dec 1, 2023 · An aluminum wire ampacity chart can help you decide which wire you can use based on temperature. 600 Volt. At Encore Wire, we always put our customers first. When used as RHW-2 or USE-2, conductor temperatures The wire size chart below shows allowable ampacities of insulated conductors rated up to and including 2000 Volts, 60°C through 90°C (140°F through 194°F), not more than three current-carrying conductors in raceway, cable, or earth (directly buried), based on ambient air temperature of 30°C (86°F). Get the best value for your money with Southwire's triplex wire service drop cable. 15 (B) (16) (formerly Table 310. 2nd Length. However, this includes taking into account the 80% NEC rule. 1st Length. 348 mm and it has a 42. Insulation Thickness: 0. Table of Contents 350 STR 3E AL USE-2 RHH-RHW-2 600V BLACK. Table of Contents But you can’t answer that question without determining the ampacity of this wire size. Standard lengths are subject to normal manufacturing tolerance of +/- 10% 3. To calculate the amperage for a circuit, first add up the wattage of all the electrical devices that will be on the circuit. 4 mm2 thickness, the 1 AWG copper wire has a current-carrying ampacity of 130 amps at 75°C. 25 /FT Sale 51% off. National Electrical Code. Aug 29, 2023 · The ampacity of 2 AWG wire is 130A at 90°C for XHHW-2 and USE. 869 inches. Specifications : Insulated Cond(s) Size AWG : 1, Bare Conductor Size AWG : 3, Nominal O. Table of Contents Wire Size & Amp Ratings. 533 inches Weight: 0. Search Amazon for your Electrical 2-2-4 Stephens Triplex Aluminum Conductor Underground Direct Burial 600V URD. Standards: Ampacities based on National Electric Code, 2005 edition, section 310-15 60°C when terminated to equipment for circuits rated 100 Amps or less or marked for 14 gauge through 1 gauge conductors 2-2-2 Conch ACSR Aluminum Triplex Overhead Service Drop Cable | WireAndCableYourWay. Conductor Strand: 7. Insulation: UL recognized cross-linked polyethylene. 81 394 120 135 125 1/0-02alumg-ser 2 x 1/0 18 1/0 18 1. Feb 21, 2024 · This chart is your go-to resource for understanding how many amps different aluminum wires can handle at various temperatures. kw ua bf mo qz xb ry yb xv rd